We are not the manufacturer, authorised distributor or authorised representative of the Aventics (brand of Emerson) brand in Ireland. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Aventics (brand of Emerson)
Country
Germany
Name
5724550220 (CD12-3/2NC-SR-024DC-I-G012-G01) AVENTICS - 3/2-Wegeventil, Serie CD12
Part number
5724550220
Description
3/2-Wegeventil, Serie CD12 CD12-3/2NC-SR-024DC-I-G012-G012-EN175301 Betätigungelektrisch Nenndurchfluss Qn4000 l/min Schaltprinzip3/2 AusführungNC/NO Druckluftanschluss AusgangG 1/2 Betriebsdruck min.2 bar Betriebsdruck max.10 bar Betriebsspannung DC24 V Spannungstoleranz DC-10% / +10% Handhilfsbetätigungrastend, nicht rastend Elektrischer Anschluss TypStecker Elektrischer Anschluss GrößeEN 175301-803, Form A Elektrischer Anschluss Anzahl Pole3-polig Betätigungsfunktioneinseitig betätigt Dichtprinzipweich dichtend Vorsteuerungintern Vorsteuerventilbreite30 mm Bauart VentilSchieberventil, überschneidungsfrei AnschlussartRohranschluss RückstellungMit Federrückstellung Temperaturbeständigkeit-25 °C kältebeständig Steuerdruck min.2 bar Steuerdruck max.10 bar Umgebungstemperatur min.-25 °C Umgebungstemperatur max.50 °C
Stock availability:
On request
Version | Spool valve, positive overlapping |
Activation | Electrically |
Sealing principle | Soft sealing |
Working pressure min./max. | See table |
Control pressure min./max. | See table |
Ambient temperature min./max. | See table |
Medium temperature min./max. | See table |
Medium | Compressed air |
Max. particle size | 50 µm |
Oil content of compressed air | 0 ... 1 mg/m³ |
Nominal flow Qn | 4000 l/min |
Nominal flow 1 ▶ 2 | 4000 l/min |
Nominal flow 2 ▶ 3 | 4000 l/min |
Compressed air connection | according to ISO 228-1 |
Pilot control exhaust | with directional pilot air exhaust |
Connector standard | EN 175301-803:2006 |
Reverse polarity protection | Protected against polarity reversal |
Compatibility index | See table |
Duty cycle | 100 % |
Weight | See table |
The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C . The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS. Further information can be found in the “Technical information” document (available in the MediaCentre). |
ATEX optional: ATEX version can be produced by combining the basic valve without coil with an ATEX coil. ATEX ID: see ATEX coils catalog page. option valve: The input and output compressed air connections can be exchanged.The valve can thereby be used in the NC or NO operating mode. *Note: Basic valves feature a maximum working pressure of 16 bar. When combined with standard CNOMO pilots, the maximum working pressure is 10 bar. |
Material |
---|
Housing | Aluminum Polyamide fiber-glass reinforced |
Seals | Acrylonitrile butadiene rubber Polyurethane |