TX3C-A024M Euchner 082953
 TX3C-A024M Euchner 082953

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand in Ireland. The private labels and part numbers shown on this website are the property of their respective owners.

Euchner TX3C-A024M 082953

Manufacturer

Euchner

Country

Germany

Name

TX3C-A024M

Part number

082953

Description

Schlüsselschalter TX3C-A024M

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications TX3C-A024M 082953

On website of FAMAGA you can buy Euchner TX3C-A024M :articul, and many other spare parts from the Euchner with delivery all over the United States , including: Dublin.For price list, delivery timings and other product features of the Euchner, please, fill in the feedback form or send a description of goods you need to our e-mail [email protected]

Features TX3C-A024M 082953

  • Auxiliary release on the front
  • Release under load possible
  • With door monitoring contact
Approach direction Horizontal and vertical Can be adjusted in 90° steps Solenoid operating voltage
  • AC/DC 24 V +10%, -15%
LED function displayThe switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage. Guard locking type
TX3Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid. Release under load possible.
Switching element
ETX CSlow-action switching contact 2 NC / 1 NO + 1 NO (door monitoring contact)
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. The auxiliary release must be sealed to prevent tampering (for example with sealing lacquer).
Housing material Die-cast alloy, cathodically dipped
Weight
Net 0,8 kg
Ambient temperature -20 ... 80 °C
Degree of protection IP67
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position NO contacts 1
Number of guard lock monitoring positively driven contacts 2
Number of guard lock monitoring NO contacts 1
Connection
3 x M20 x 1.5
Approach speed
max. 20 m/min
Actuation frequency 1200 1/h
Guard locking principle Closed-circuit current principle
Locking force Fmax 1700 N
Locking force FZh 1300 N
Retention force min.50 N
Extraction force 35 N
Actuating force 35 N
Insertion depth min.32 mm
Electrical connection ratings
Thermal rated current Ith 4 A
Utilization category according to EN 60947-5-1
AC-15 4A 230V
DC-13 4A 24V
Solenoid operating voltage
AC/DC 24 V -15% ... +10%
Short circuit protection according to IEC 60269-1
(Fuse) 4A gG
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Power consumption 8 W
Solenoid duty cycle 100 %
Connection cross-section 0,34 ... 1,5 mm?
LED indicator Operating voltage corresponds to the solenoid voltage
Reliability values according to EN ISO 13849-1
Control of the guard locking
Category Depending on external control of guard locking
Performance Level Depending on external control of guard locking
PFHD Depending on external control of guard locking
Monitoring of guard locking and the safety guard position
B10D 6 x 106
In combination with Actuator BETAETIGER-X-GQMechanical values and environment
Overtravel 1 mm
In combination with Actuator BETAETIGER-X-GNQMechanical values and environment
Overtravel 8 mm