We are not the manufacturer, authorised distributor or authorised representative of the IFM brand in Ireland. The private labels and part numbers shown on this website are the property of their respective owners.
Electrical design | PNP |
Output function | normally open / normally closed; (parameterisable) |
Sensing range [mm] | 8 |
Dimensions [mm] | M18 x 1 / L = 68 |
Special feature | Gold-plated contacts |
Application | evaluation of rotating and linear movements with regard to underspeed; blocking |
Nominal voltage DC [V] | 10...36 |
Current consumption [mA] | 15 |
Protection class | II |
Reverse polarity protection | yes |
Electrical design | PNP |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2.5 |
Permanent current rating of switching output DC [mA] | 150; (when used outside the hazardous area: 250; Pulse output: 15) |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Sensing range [mm] | 8 |
Sensing range adjustable | no |
Operating distance [mm] | 0...6 |
Setting range [Imp/min] | 3...6000 |
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.4 / copper: 0.3 |
Hysteresis [% of Sr] | 10 |
Start-up delay [s] | 0...15 |
Max. damping frequency [Imp/min] | 18000 |
Adjustment of the switch point | Teach function |
Ambient temperature [°C] | -20...50 |
Note on ambient temperature | when used outside the hazardous area: -20...60 °C |
Storage temperature [°C] | -25...60 |
Protection | IP 67 |
ATEX marking | II 3D Ex tc IIIC T80°C Dc IP67 U |
Note on ATEX marking | only in conjunction with the impact protection housing |
EMC | EN 60947-5-2 |
MTTF [years] | 1051 |
Weight [g] | 177 |
Mounting | non-flush mountable |
Dimensions [mm] | M18 x 1 / L = 68 |
Thread designation | M18 x 1 |
Materials | stainless steel (1.4571/316Ti ); PBT; TPE-U |
Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |