Electronic data | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Voltage [V] | 18... 30 DC | ||||||||||
Current consumption [mA] | <150 | ||||||||||
Protection class | III | ||||||||||
Power protection | da | ||||||||||
Type of light | red light | ||||||||||
Wavelength [nm] | 650 | ||||||||||
Stand. lifetime [h] | 50000 | ||||||||||
Inputs/outputs | |||||||||||
Number of inputs and outputs | Number of digital outputs: 2, Number of analog outputs: 1 | ||||||||||
Outputs | |||||||||||
Total number of outputs | 2 | ||||||||||
Electrical version | PNP | ||||||||||
Number of digital outputs | 2 | ||||||||||
Output function | normally open / normally closed, (programmable) | ||||||||||
Max. allowable current load per output [mA] | 200 | ||||||||||
Number of analog outputs | 1 | ||||||||||
Current analog output [mA] | 4...20, (IEC 61131-2) | ||||||||||
Sub. load [?] | 250 | ||||||||||
Voltage analog output [V] | 0...10, (IEC 61131-2) | ||||||||||
Min. load resistance [?] | 5000 | ||||||||||
Short-circuit protection | yes | ||||||||||
Short-circuit protection type | total | ||||||||||
Power overcurrent protection | yes | ||||||||||
Max. light Spot width [mm] | 8 | ||||||||||
Max. height of the light spot [mm] | 8 | ||||||||||
Dimension of the light spot in relation to | 6 m | ||||||||||
Background suppression [m] | 6...100 | ||||||||||
Measuring/setting range | |||||||||||
Measuring range [m] | 0.3... 6, (white paper 200 x 200 mm) | ||||||||||
Sampling Rate [Hz] | 1...33 | ||||||||||
Interfaces | |||||||||||
Communication Interface | IO-Link | ||||||||||
The transmission method | COM2 (38.4 kBaud) | ||||||||||
IO-Link Check | 1. 1 | ||||||||||
SDCI standard | IEC 61131-9 | ||||||||||
IO-Link device ID | 812 d / 00 03 2 Ch | ||||||||||
Profiles | Smart Sensor: Sensor Identification, Binary Data Channel, Process Value, Sensor Diagnosis | ||||||||||
SIO mode | yes | ||||||||||
Port type desired | A | ||||||||||
Analog operating data | 2 | ||||||||||
Binary operating data | 2 | ||||||||||
minimal [ms] | 6 | ||||||||||
Operating conditions | |||||||||||
Environmental temperature [°C] | -10... 60 | ||||||||||
Protection degree | IP 67 | ||||||||||
Tests / Approvals | |||||||||||
EMS |
EN 60947-5- 2 |
Attention: | laser |
laser class: | 1 | EN / IEC60825-1:2007 |
EN / IEC60825-1:2014 | |
Complies with regulation 21 CFR 1040, except for deviations described in Laser Notice No. 50, which is dated July 2007. |
Status output | 2 x LED, yellow |
operating mode | LED, green |
range, programming | letter-digital display, 4-digit |
Shield cover, E21133 |
Power supply voltage "supply class 2" according to cULus | |
Packing value | 1 pc. |
electrical connection | |
---|---|
Connection | Socket: 1 x M12 |