IFM SM8000
  IFM SM8000

We are not the manufacturer, authorised distributor or authorised representative of the IFM brand in Ireland. The private labels and part numbers shown on this website are the property of their respective owners.

IFM SM8000

Manufacturer

IFM

Country

Germany

Part number

SM8000

Description

Magnetic-inductive flow meter

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications SM8000

On website of FAMAGA you can buy IFM :articul, and many other spare parts from the IFM with delivery all over the United States , including: Dublin.For price list, delivery timings and other product features of the IFM, please, fill in the feedback form or send a description of goods you need to our e-mail [email protected]

Features SM8000

Application
ApplicationSum function, for general industrial use
Installationpipe connection with adapter
MediumConductive liquids, Water, water-based liquids
Medium note
Conductivity: ? 20 µS/cm
Viscosity: < 70 mm?/s (40 °C)
Measured medium temperature [°C]-10…70
Pressure strength [bar] 16
MAWP (for use according to CRN) [bar]11.2
Electronic data
Operating voltage [V]18…30 DC, (according to EN 50178 SELV/PELV )
Current consumption [mA]95, (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs/outputs
Number of inputs and outputsNumber of digital outputs: 2, Number of analog outputs: 1
Inputs
Inputsreset counter
Outputs
Total number of outputs2
Output signalSwitching signal analog New signal, pulse signal, IO-Link, (configurable)
Electrical versionPNP/NPN
Number of digital outputs2
Output signal functionnormally open / normally closed, (parameterizable)
Max. voltage drop DC switching output [V]2
DC switching output load current [mA]200
Number of analog outputs1
Analog current output [mA] 4…20, (scalable)
Max. load [?]500
Analog voltage output [V]0…10, (scalable)
Min. load resistance [?]2000
Pulse outputFlowmeter
Short-circuit protectionyes
Short-circuit protection typeclocked
Overcurrent protectionyes
Measurement/setting range
Range measurements
0.2…100 l/min0.01…6 m?/h
Display range
-120…120 l /min-7.2…7.2 m?/h
Resolution
0.1 l/min0.005 m?/h
Setting point SP
0.7…100 l/min0.04…6 m?/h
Reset point rP< /tr>
0.2…99.5 l/min0.01…5.97 m?/h
The starting point of the analog signal, ASP
0…80 l/min0…4.8 m?/h
Analogue end point, AEP
20…100 l/min1,2…6 m?/h
Width step
0.1 l/min0.005 m?/h
Momentary flow control
Pulse value0.00001 …100 000 m?
Pulse length [s]0.0025…2
Temperature control
Measuring range [°C]-20…80
Resolution [°C]0.2
Setting point SP [°C]-19.2…80
Reset point rP [°C]-19.6…79.6
Analog start point [°C]-20…60
Analogue end point [°C]0…800…80
In steps of [°C]0.2
Accuracy/Uncertainty
Flow rate control
Accuracy (in measuring range)± (0.8 % MW + 0.5% MEW)
Repeatability± 0.2% MEW
Temperature control
Accuracy [K]± 2.5 (Q > 5 l/min)
Response Time
Flow Rate Control
Response time [s]0.15, (dAP = 0)
Programmable delay time dS, dr [s] 0…50
Switching output damping dAP [s]0…5
Temperature control
Dynamics of response response T05 / T09 [s]T09 = 20 (Q > 5 l/min )
Software / Programming
Parameter selectionFlow rate control, flow meter, counter with presetting, Temperature control, hysteresis / window, normally open / normally closed, switching logic, current output / voltage output / pulse output, Start delay, display can be switched off, Display
Interfaces
Communication interfaceIO-Link
Transmission methodCOM2 (38.4 kBaud)
IO-Link test1.1
SDCI standard IEC 61131-9
IO-Link Device ID575 / 00 02 3f
ProfilesSmart Sensor: Process Data Variable, Device Identification, Device Diagnosis
SIO modeyes
Desired port typeA
Analog operating data3
Binary operating data2
Min. cycle time [ms]5
Operating conditions
Ambient temperature [°C]-10…60
Storage temperature [°C]-25…80
Degree of protectionIP 67
Tests / approvals
EMC
DIN EN 60947-5-9
Impact resistance
DIN IEC 68-2-2720 g (11 ms)
Vibration resistance
DIN IEC 68-2-65 g (10…2000 Hz)
MTTF [g Code]145
Pressure Equipment DirectiveGood engineering practice, can be used for fluid group 2, group liquids 1 on request
Mechanical data
Weight [g]641.5
Materialstainless steel steel (1.4404 / 316L), PBT-GF20, PC, FKM, TPE mediumstainless steel steel (1.4404 / 316L), PEEK, FKM
Process connectionG 1 DN25 threaded connection Flat seal
Displays / Controls
Display
Display6 x LED, green (l/min, m?/h, l, m?, 10?, °C)
Output status 2 x LED, yellow
Measured valuesalphanumeric display, 4 digits
programmingalphanumeric display, 4 digits
Notes
Notes
MW = Measured value
MEW = Upper limit of measuring range
Pack quantity1 piece
electrical connection
ConnectionConnector: 1 x M12, Contacts: gold-plated
Diagrams and Graphs
Pressure Loss
dPPressure loss
Qvolumetric consumption