IFM TA2512
  IFM TA2512

We are not the manufacturer, authorised distributor or authorised representative of the IFM brand in Ireland. The private labels and part numbers shown on this website are the property of their respective owners.

IFM TA2512

Manufacturer

IFM

Country

Germany

Part number

TA2512

Description

Temperature transmitter with high precision across the entire temperature measurement range

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications TA2512

Hygienic design for the requirements of the food and beverage industry. Particularly good response dynamics and very short power-on delay time. Precise analogue output and user-friendly communication via IO-Link. Robust stainless steel housing with high protection rating and high pressure rating.

Features TA2512

Shock resistance< /tr>< /tbody>
Application
Measuring element1 x Pt 1000, (to DIN EN 60751, class A)
MediaLiquid or gaseous media
Pressure strength [bar]160
Vacuum resistance [mbar]-1000
MAWP ( for use according to CRN) [bar]160
Electronic data
Operating voltage [V]18…32 DC, ("supply class 2" according to cULus)
Current consumption [mA]< 50
Protection classIII
Reverse polarity protection yes
Power-on delay time [s]2
Inputs/outputs
Number of inputs and outputsNumber of analog outputs: 1
Outputs
Total number of outputs1
Output signalanalog signal, IO-Link, (configurable)
Number of analog outputs1
Analog current output [mA]4…20
Maximum load [?]250, ((18…19 V), 19…32 V: 300 ? )
Short circuit protectionYes
Overcurrent protectionyes
Measuring/setting range
Measuring range [°C]- 50…200
Factory setting0…200 °C
Resolution< /th>
Analog output resolution [K]0.04
Accuracy/error
Analog output accuracy [K]± 0.3 + (± 0.1 % MS)
Temperature coefficient [% of measuring range / 10 K]0.1, (When deviating from standard conditions 25 ± 5 °C)
Response time
Dynamics of response T05 / T09 [s]< 0.5 / < 2
Interfaces
Communication interfaceIO-Link
Transmission methodCOM2 (38.4 kBaud)
IO-Link test1.1
Operating conditions
Ambient temperature [°C]-25…80
Ambient temperature note
at medium temperature: < 160 °C
-25…60 °C
at medium temperature: < 200 °C
Storage temperature [°C]-40…100
Degree of protectionIP 67, IP 68, IP 69K
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
DIN IEC 68-2-2750 g (11 ms)
Vibration resistance< /tbody>
DIN IEC 68-2- 610 g (10…2000 Hz)
MTTF [years]232
UL certified
UL registration numberK002
Mechanical data
Weight [g]183
Dimensions [mm]O 18.7
Materialstainless steel steel (1.4404 / 316L), PEI, FKM mediumstainless steel steel (1.4404 / 316L) electropolished
Process connectionG 1/2 threaded connection Cone seal
Surface characteristic Ra/Rz of the parts in contact with the mediumRa: < 0.8
Probe diameter [mm]6
Installation length EL [mm]50
Notes
Notes
MS = measuring interval setting
Values accuracy refer to running water.
Packing quantity1 piece
Electrical connection
ConnectionConnector: 1 x M12